Hydropneumatic setting tool for the installation of KOENIG EXPANDER®. Quick tool change avoids long changeover times. The required working stroke is preprogrammed and can be retrieved by the Expander type to be processed (max. 64 memory locations). In addition, the working stroke is referenced for each individual Expander, which guarantees high process stability and quality. The press is force and distance controlled; an RS232 or USB interface can be used to trace corresponding data on the customer’s computer for later processing. The required software is included in the scope of delivery.
For the installation of KOENIG EXPANDER Series MB, and CV from Ø 3 – 10mm (.156″ – .375″inch), KOENIG CHECK VALVE BF and BR 5.5 and 8mm, and KOENIG RESTRICTOR Series RE from Ø 4 – 10mm.
For the installation of KOENIG EXPANDER Series MB and CV Ø 12 – 22mm (.406″ – .437″ inch).
| SETTING TOOL DATA | |||||||||
| Express 3000 | Express 5000 | ||||||||
|---|---|---|---|---|---|---|---|---|---|
| Height | approx. 1360 mm | Height | approx. 1450 mm | ||||||
| Width | approx. 410 mm | Width | approx. 448 mm | ||||||
| Depth | approx. 570 mm | Depth | approx. 652 mm | ||||||
| Table (width x depth) | 250 x 180 mm | Table (width x depth) | 250 x 180 mm | ||||||
| Weight | approx. 185 kg | Weight | approx. 210 kg | ||||||
| Compressive Force | 28 kN | Compressive Force | 48 kN | ||||||
| Working Stroke | 10 mm (within the cylinder ram) | Working Stroke | 10 mm (within the cylinder ram) | ||||||
| Working Speed | 40 mm/sec (max. possible at 6 bar) | Working Speed | 30 mm/sec (max. possible at 6 bar) | ||||||

| SETTING TOOL DATA | |||||||||
| Express 3000 and Express 5000 | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| Working area (height) | 250 mm (working height between table top and cylinder, without setting tool) | ||||||||
| Working area (depth) | 200 mm (center-line spacing between cylinder and C frame) | ||||||||
| Cylinder ram | 60 mm | ||||||||
| Operating voltage | 230 V/110V, automatic switchover to corresponding power supply | ||||||||
| Operation | VISUAL POINT terminal with QVGA graphic display | ||||||||
| Force/distance control | Sensor adjusted with SIT reference sensor | ||||||||
| Software | WINSCOPE Software for connecting to a PC | ||||||||